SKU/Artículo: AMZ-B0DJNSX8SH

INSTRUKART

Clean Room Oxygen Monitor (Range: 0 to 25% Vol) for Nitrogen Purging, Pharmaceuticals, Chemical Labs, Clean Rooms Model: Ace Al-CL-O2 Clean Room Oxygen Monitor

Model:

Ace Al-CL-O2 Clean Room Oxygen Monitor

(RS485 communication + Relay optional )

Ace Al-CL-O2 Clean Room Oxygen Monitor

Standard commmunication RS485

Detalles del producto
Disponibilidad:
En stock
Peso con empaque:
0.50 kg
Devolución:
Condición
Nuevo
Producto de:
Amazon
Viaja desde
USA

Sobre este producto
  • The Ace Instruments make Oxygen Monitor is a weatherproof indicator transmitter with 4 digit, 7 segment red LED Display. Optionally available with 1 Relay Output & a built in buzzer alarm for process violation alert. 1) The Oxygen Monitor has an optional RS 485 Modbus Protocol Communication output to connect to PLC/ SCADA / BMS Software. 2) Large & clear 4-digit red LED Display, 7 segment type. 3) 1 Relay Output (NO/ CO/ NC). 4) In-built buzzer for high & Low Limits Violation Alert. 5) RS 485 Modbus Communication for PC/ SCADA/ BMS/ EMS/ PLC Integration.6) Easily field replaceable Sensor Module.
U$S 384,00

IMPORTÁ FACIL

Comprando este producto podrás descontar el IVA con tu número de RUT

AHORA EN FRANQUICIA

U$S 384,00
Llega en 11 a 15 días hábiles
con envío
Tienes garantía de entrega
Este producto viaja de USA a tus manos en

Conoce más detalles

Features: The cleanroom oxygen monitor measures oxygen levels from 0.0% to 25.0% | the oxygen Indicator comes with a clear 4-digit LED display, 0.56” in height | In-built buzzer alarm for alert in case of Oxygen Set Point Violation (user selectable limits). A buzzer acknowledgment switch is provided on the front plate | RS 485 Modbus communication to connect BMS/EMS Systems Model: AI-CL-O2 | Measuring Range: 0 to 25% O2 | Accuracy: +/- 1% F.S | Display: 4 digit, 0.56” High, 7 segment red LED display | Response Time: Approx. 15 seconds | Enclosure: Mirror finished front stainless steel flush plate with MS back box | Sensor Type: Japanese Electro-chemical type, quick response, no CO2 influence | Buzzer: Built-in Buzzer with alarm for low and high limit violation alert & acknowledgment key | Power Supply: 24 V.D.C, 350 mA/ Optional 230 VAC adaptor provided | Sensor Life: Approx 3 years, after which oxygen sensor is directly replaceable on field Supply Scope: 1 Unit of CL-O2 Clean Room Oxygen Monitor, Power Adaptor, Instruction Manual and Factory Calibration Certificate | Applications: Pharmaceuticals, Chemical Labs, Clean Rooms, Nitrogen Purging.