SKU/Artículo: AMZ-B0DRNBX92Q

Eujgoov

Eujgoov 5Pcs Timer Module, Timer Switch Turn On Off Relay Module with LED Display DC 5V-36V

Disponibilidad:
En stock
Peso con empaque:
0.36 kg
Devolución:
No
Condición
Nuevo
Producto de:
Amazon

Sobre este producto
  • To achieve fast turn-on and off circuit, an unlimited number of switching times
  • No noise was made during turning on/off, no spark, and no electromagnetic interference
  • Compared to normal electromagnetic relay modules, it has a longer service life
  • Dual-MOS in parallel active output, lower inner , larger current, strong power; at room temperature, operating current is up to 15A, power up to 400W, that can be used for most equipment
  • Wide voltage input from 5V to 36V, normally used for controlling DC motors, lights, LED strips, micro-pumps, solenoid valves, etc., very convenient
U$S 20,34
44% OFF
U$S 11,30

IMPORTÁ FACIL

Comprando este producto podrás descontar el IVA con tu número de RUT

U$S 20,34
44% OFF
U$S 11,30

¡Comprá en hasta 12 cuotas sin interés con todas tus tarjetas!

Llega en 25 o más días hábiles
con envío
Tienes garantía de entrega
Este producto viaja de USA a tus manos en
Medios de pago Aceptamos múltiples medios de pago para tu comodidad

Compra protegida

Disfruta de una experiencia de compra segura y confiable

Conoce más detalles

Specifications: Voltage: DC 5V~36V. Trigger Source: High voltage level trigger (3.0V~24V), ground and system ground are not on common ground to improve the system's anti-jamming capability (you can also connect them on common ground). Output Capacity: DC 5V~36V, at room temperature, continuous current is 15A, power 400W. With enhanced heat dissipation, the current can be up to 30A. Quiescent Current: 20mA Operating Current: 50mA Working Temperature: -40℃~85℃ Clocking (Time Delay) Range: 0.1 seconds to minutes Size: 60*34*12 mm / 2.36*1.33*0.47 Instruction: Operating Mode: P1: trigger signal, the relay is onOP time, and then disconnect; in the OP time, as follows: P1.1: is triggered again, invalid P1.2: is triggered again, the clocking is reset P1.3: is trigger again reset, relay off, and stop the clocking; P-2: trigger signal, the relay offCL of time, the relay on OP time, and then disconnect relay after clocking; P3.1: trigger signal, the relay is turned on after the OP time, the relay off CL time, then the cycles; if trigger again during the cycle, the relay off, stop clocking; the number of cycles times ( LOP ) can be set. P3.2: without triggering after power on, the relay is on OP time, the relay off CL time, then the cycles; the number of cycles times ( LOP ) can beset. P-4: holding function. If there is trigger signal, clocking is reset, the relay remains on; when the disappears,after clocking OP time, the relay is off; if another istriggered during clocking, clocking will be reset.