MTDELE 3Pcs 6-30V Timer Relay Module Programmable Delay with LED Display Cycle Timer Supports Micro USB 5.0V
En stock
0.36 kg
Sí
Nuevo
Amazon
USA
- Working mode:P1: After the trigger signal is given, the relay is energized for OP time and then disconnected; during the OP time, the operation is as followsP1.1: Invalid signal triggers againP1.2: Re-timing signal triggers againP1.3: Reset signal triggers again, the relay disconnects, and the timing stops;P-2: After the trigger signal is given, the relay is energized for CL time, the OP relay conduction time, and after the timing ends, the relay is disconnected;P3.1: After the trigger signal is given, the relay is energized for OP time, the relay is disconnected for CL time, and then the operation is cyclic. After the trigger signal is given, the relay is disconnected and the cycle stops again Stop timing; the number of cycles (LOP) can be set;P3.2: After power on, there is no trigger signal, the relay is OP time, the relay is CL time, and the cycle operation is cyclic; the number of cycles (LOP) can be set;P-4: If there is a trigger signal, the signal retention function is reset, and the relay remains energized; when the signal disappears, the timing is completed and the OP relay is disconnected; when the timing cycle ends, the signal appears again, and the timing is reset;Timing setting:After setting the parameter value in the mode selection screen, press the STOP key shortly to select the timing range;Decimal point XXX digits, timing range: 1 second ~ 999 secondsDecimal point XX.X tens place, timing range: 0.1 seconds ~ 99.9 secondsX.X.X. decimal point is fully lit, timing range: 1 minute ~ 999 minutesFor example, if you want to set OP to 3.2 seconds, move the decimal point to the tens place, and the digital tube displays 03.2Parameter description: OP power-on time, CL power-off time, LOP cycle times (1 ~ 999 times, "---" represents infinite loop)These parameters are independent of each other, but these mode parameters have commonalities. For example, P1.1 sets the OP power-on time to 5 seconds. If the user wants to switch to P1.2 mode, enter P1.2 to set the corresponding parameters, and OP will be 5 seconds;Pressing the SET button on the main interface (displaying 000) will display OP (CL, LOP) and the corresponding time XXX;If you only set the timing of the OP mode (such as modes P1.1, P1.2, P1.3), pressing the SET button will only display OP and the corresponding time;If there are OP, CL, LOP in the mode (such as modes P3.1, P3.2), press the SET button to display OP and the corresponding time, CL and the corresponding time, LOP and the corresponding number;In the setting mode, you can easily see the current setting mode parameters by short pressing the SET button on the main interface, which is very convenient!Parameter setting:1. First determine the working mode of the relay;The working mode of the relay, in the main interface (when the module is powered on, the current working mode (P1.1 default mode) flashes and displays, and then enters the main interface) "Press and hold the SET key for 2 seconds and release it" to enter the mode selection interface and press the UP and DOWN keys to select the mode to be set (P1.1~P-4);3. After selecting the mode to be set (for example, P3.2), press the SET key to set the corresponding parameters. At this time, the parameters to be set flash (OP on-off time, CL power-off time, LOP cycle times ("- - " stands for infinite loop)) Adjust the value through UP and DOWN, support long press (quick increase or decrease) and long press (increase or decrease one unit); when setting the parameter value, press the STOP key to select the decimal point position and the time range (corresponding to 0.1 seconds to 999 minutes); short press the SET key to set the next parameter of the current mode, the process is the same as above;4. After setting the parameters of the selected mode, press and hold the SET key for 2 seconds and then release it. The currently set mode will flash, and then return to the main interface. It is very simple to set the parameters successfully!Main interface: "000" (no decimal point) is displayed when the relay is not working, and there is a decimal point when the relay is working, which is very clear!Mode selection interface: long press SET to enter, after setting, press the SET key to exit and return to the main interface, the operation is very simple!STOP key function:Relay enable mode:1. ON: The internal OP time relay is allowed to conduct;2. OFF: The relay is prohibited from conducting and is always closed;In the main interface, short press the STOP key to switch between ON and OFF, the current state will flash, and then return to the main interface. (This function is an emergency stop function, one-key disconnection of the relay closure)Sleep mode:1. C-P sleep mode: No operation for five minutes, the digital tube display automatically turns off, and the program runs normally;2. O-d normal mode: The digital tube display is always on;Press the STOP key for two seconds and then release it to switch between C-P and O-d states. The current state flashes and then returns to the main interface.
IMPORTÁ FACIL
Comprando este producto podrás descontar el IVA con tu número de RUT
Conoce más detalles
Timer Relay:Compatible with for Smart Control for Electrical Appliances Electronic Equipment Lamps etc Size:63*37.5mm Volts:6-30V Static current:20mA Operating current:50mA Commodities include:3Pcs Timer Relay;1Pcs Screwdrivers