SKU/Artículo: AMZ-B08C7KHMCC

Fireye

M-Series II Programmer Module with Relight Function

Disponibilidad:
En stock
Peso con empaque:
0.62 kg
Devolución:
No
Condición
Nuevo
Producto de:
Amazon
U$S 1.538,58
60% OFF
U$S 615,43

IMPORTÁ FACIL

Comprando este producto podrás descontar el IVA con tu número de RUT

U$S 1.538,58
60% OFF
U$S 615,43

¡Comprá en hasta 12 cuotas sin interés con todas tus tarjetas!

Llega en 15 a 25 días hábiles
con envío
Tienes garantía de entrega
Este producto viaja de USA a tus manos en
Medios de pago Aceptamos múltiples medios de pago para tu comodidad

Compra protegida

Disfruta de una experiencia de compra segura y confiable

Conoce más detalles

M-Series II Programmer Module with Relight FunctionFireye Modular M-Series II Flame Protection Controls are compact, modular burner management systems. They provide automatic ignition and continuous flame monitoring for commercial size heating and process burners using gas and/or light oil fuels. Flame detection is accomplished by miniature UV scanners or flame rod/photocell detectors and plug-in programmer and amplifier modules connected to a standard chassis and wiring base. Interchangeable programmer and amplifier modules allow complete versatility in selecting control function, timing, and flame scanning media. Functions such as relight, two-stage capability, purge timing, and pilot shutoff are determined by the programmer module. Flame scanner type (UV, flame rod, or photocell) and flame failure response time (FFRT) are determined by the amplifier module. Some programmer modules have switches to select purge time, pilot rehearsal for ignition (PTFI) time, and recycle or non-recycle operation. LED indicator lights on all programmer modules indicate the operating status of the control. In the event of a misfire, or after a safety shutdown, the unit locks out, activating an alarm circuit. Manual reset is required. Remote reset (via remote pushbutton or power interruption) is available on the MC120R chassis. Post-purge is available on the MC120P chassis. Test connectors allow measurement of the flame signal during operation. A "run check" switch on the MP560, MP561, MP562 programmer module assists in testing pilot size, position, and stabilization. The M-Series II modular controls incorporate a safety check circuit that is operative at every start. If flame (real or simulated) is detected prior to a start or during purge, the fuel valves will not activate and the till will lock out. Specifications: Product type: control module. Features: Relight Operation