SKU/Artículo: AMZ-B0DNSL4VJN

Brilluxa

PLC Controller, Programmable Logic Controller Board Industrial Control Module 3U 32MR with RS485 CAN, Automation Control Board with Housing and Base for Machine I/O Control

Size:

Housing with base

Disponibilidad:
En stock
Peso con empaque:
0.55 kg
Devolución:
No
Condición
Nuevo
Producto de:
Amazon

Sobre este producto
  • PLC supports 2 channels of 232, one of which is used to write monitoring programs
  • The CPU adopts imported STM32F103 series, the download speed is extremely fast, basically downloading in seconds, mainly to save labor time in batches.
  • All relays use imported high‑quality relays, relay contacts, AC no more than 5A 250V, DC no more than 30V 5A.
  • Can be used for touching screen communication, extended temperature, pressure, etc.
  • This board is a PLC board, directly use programming software to compile ladder diagrams, write directly to PLC, and online monitoring
U$S 118,91
31% OFF
U$S 82,01

IMPORTÁ FACIL

Comprando este producto podrás descontar el IVA con tu número de RUT

U$S 118,91
31% OFF
U$S 82,01

¡Comprá en hasta 12 cuotas sin interés con todas tus tarjetas!

Llega en 25 o más días hábiles
con envío
Tienes garantía de entrega
Este producto viaja de USA a tus manos en
Medios de pago Aceptamos múltiples medios de pago para tu comodidad

Compra protegida

Disfruta de una experiencia de compra segura y confiable

Conoce más detalles

Input Power: DC24VProgram Steps: 8000 stepsCommunication Port: 2 x Communication Port: : 2 x RS232 (standard 9-pin serial port FX3u protocol 38400, 7, E, 1) 1 x RS485Input Point X Component: X0-X17, DC24 input, low level active. Among them X0-5 is the high-speed counting input port (12KHZ)Output Point Y Components: Y0-Y17 are relay outputs, all imported relays are used; Relay contacts: AC not greater than 5A 250V; DC not greater than 30V 5AAnalog Input: 6 Channels Of Analog Input, 12-bit Accuracy, AD0~AD2 Are Voltage input: 0-10V, AD3~AD5 are 0-20MA current input; use RD3A command to read analog quantityAnalog Output: 2 Analog Outputs, 12-bit Accuracy, Output Voltage: 0-10V. WR3A command for output analog voltageIntermediate Relay M: M0-M3071, save range can be set M0-M1023Step Point S: S0-1023, save range can be set S0-S1023100Ms Timer: T0-T199, accumulative power-down save T184-T19910Ms Timer: T200-T249, accumulative power-down save T246-T2491Ms Timer: T250-T383, of which T250-255 is cumulative16-Bit Counter: C0-C199, C100-19932-Bit Counter: C200-C219, save C220-C234 when power off32-Bit High-Speed Counter: C235-255; C235-240 is a single-phase counter without frequency multiplication; C241-240 is a single-phase counter with 2 times frequency; C247-249 is a two-phase counter without frequency multiplication; C250-252 is double Phase counter, 2 times frequency; C253- is two-phase counter, 4 times frequency;Register D: D0-D7999, the save range can be set D0-7999,Indirect Addressing Pointer V, Z: V0-7, Z0-7P Subroutine Jump Number: P0-63I Interrupt: X0-5 external interrupt. Timer interrupt (1MS as the unit). The counter is interrupted.Special M Part: M8000 is normally closed when running, M8002 is power-on pulse, M8011 is 10Ms pulse, M8012 is 100Ms pulse