SKU/Artículo: AMZ-B0G4C3MMNN

Kvsyykii

Split Type Current Button Fixed Square Hole CT 50-60HZ 1000A/5A for Electrical Energy Meter Current Sensor(600A)

Color:

600a

Disponibilidad:
En stock
Peso con empaque:
0.36 kg
Devolución:
No
Condición
Nuevo
Producto de:
Amazon

Sobre este producto
  • Current Sensors
  • Split Type Current Button Fixed Square Hole CT 50-60HZ 1000A/5A For Electrical Energy Meter Current Sensor
U$S 190,44
49% OFF
U$S 97,66

IMPORTÁ FACIL

Comprando este producto podrás descontar el IVA con tu número de RUT

U$S 190,44
49% OFF
U$S 97,66

¡Comprá en hasta 12 cuotas sin interés con todas tus tarjetas!

Llega en 15 a 25 días hábiles
con envío
Tienes garantía de entrega
Este producto viaja de USA a tus manos en
Medios de pago Aceptamos múltiples medios de pago para tu comodidad

Compra protegida

Disfruta de una experiencia de compra segura y confiable

Conoce más detalles

Current SensorsDescribeDetachable opening and closing, with double-sided press opening and closing designDust proof wiring coverFlame retardant shellSpecificationsWorking frequency: 50-60HzRated input: 100-5000ARated output:. 5AVoltage level: 0.66/0.72KVInsulation strength: 2.5KV/1mA/1minProduct shell: Load PA/UL94-VOProduct core: silicon steelProduct winding: pure copperWorking humidity: 85%Working temperature: -25 ° C+75 ° COutput connections: terminal connectionsInsulation resistance: DC500V/100M minInstallation method: fixed with two buttonsPackage included1 × Button current Instructions for use1. This series of current are indoor devices with a rated frequency of 50-60 Hz, used for measuring current, measuring electrical energy, and relay protection in AC lines.2. It is strictly prohibited to open the secondary end of the current , otherwise high-voltage electricity will be generated!!! The open close type should first connect the secondary circuit, and then attach the to the cable.3. During the withstand voltage test, the withstand voltage for the first time to the secondary and ground is 3 kV, and the side effect for the second time to ground is 3 kV, both lasting for one minute.4. The is suitable for the following working conditions:(1) Altitude not exceeding 1000 meters(2) The surrounding medium temperature is -30 ° C to+40 ° C(3) More than 85% relative humidity in the air(4) Places without explosion hazards, excessive dust, and chemically corrosive gases.5. The is allowed to be used for a long time at 110% of the rated current state under rated secondary loadCommon problems and solutions1, There is vibration noise after installation of the open close product1. Check if the product is operating under overload, and the actual current is more than 1.2 times the rated current of the .If so, please replace the high magnification .2. Dirt has adhered to the middle two magnetic cores of the . Please use a clean gauze to wipe it clean. When opening the , be careful not to let sand and dust stick to the surface of the magnetic core, which may cause poor product contact3. Is S1 and S2 open circuit? If there is an open circuit, the product will make a noise and there is a risk of generating high voltage.4. If the four fixing screws on the product are tightened too tightly and the two opening and closing surfaces of the are opened, there will be a sound if there is poor contact.2, Inaccurate measurement1. Please do not connect too many leads. Each product has a capacity, and the lower the normal current ratio, the shorter the leads that can be connected. Try to connect the leads as short as possible, and use thicker wires, usually 1.5 square meters.2. The direction of P1 and P2S1 and S2 wiring methods should be consistent, with a set of three, and even if one is reversed, it will also affect the measurement.3. The difference between the actual current and the rated current of the is too far. For example, for a 200/5 , measuring a few amperes to tens of amperes of current is not very accurate, and the closer it is to 200A, the higher the accuracy4. Poor product contact, such as uneven alignment of product magnetic cores, dirt sticking to the closed middle of the opening, and noise, all have a certain impact on accuracy3, WiringS1 incoming line; Normal correspondence to the electrical energy band+interface. S2 outgoing line; The normal corresponding meter does not come with a+interface. Current direction: in the same direction as the arrow on the label (P1 in P2 out: for example, P1 switch/P2 load)==========Hign-concerned Chemical : NoneModel Number : TY82Phase : SINGLEUse : Currentcurrent : 400A 500A 600A 800A 1000AFrequency : 50-60HZInstallation method : fixed with two buttonsAttachment : Four screws